Operation with Rechargeable Battery

Lithium-ion rechargeable batteries are supplied partially charged according to international transport regulations. To ensure full rechargeable battery capacity, fully charge the rechargeable battery before using your tool for the first time.

If the rechargeable battery is removed from the measuring tool, its state of charge may be indicated by the green LEDs of the battery charge indicator on the battery.

Press the button for the battery charge indicator or to show the state of charge.

If no LED lights up after pressing the button for the battery charge indicator, then the battery is defective and must be replaced.

Not all battery types have a battery charge indicator.

Rechargeable battery type GBA 18V... | GBA18V...

LED

Capacity

3× continuous green light

60–100 %

2× continuous green light

30–60 %

1× continuous green light

5–30 %

1× flashing green light

0–5 %

 

Battery model ProCORE18V… | EXPERT18V… | EXBA18V… | CORE18V…

LED

Capacity

5 × continuous green light

80–100 %

4 × continuous green light

60–80 %

3 × continuous green light

40–60 %

2 × continuous green light

20–40 %

1 × continuous green light

5–20 %

1 × flashing green light

0–5 %

‎EXPERT18V…‎‎‎‎ | ‎EXBA18V…‎‎‎‎‎

In addition to the state of charge of the rechargeable battery, the LEDs on the battery charge indicator can also indicate the risk of a battery defect.

To activate the function, press and hold the button for the battery charge indicator for 3 seconds. The analysis of the battery is signalled by a moving light on the battery charge indicator. The result of is shown on the battery charge indicator.

1 LED: The rechargeable battery has a high defect risk. Performance and runtime may already be reduced. Replacing the rechargeable battery is recommended.

5 LEDs: The rechargeable battery is in good condition and has a low defect risk.

Please note: The rechargeable battery defect risk assessment works in a binary manner and offers a simplified status assessment, indicating either that the rechargeable battery is in good condition or that the rechargeable battery has an increased defect risk. A percentage of the battery status is not shown.

Protect the battery against moisture and water.

Only store the battery within a temperature range of −20 to 50 °C. Do not leave the battery in your car in the summer, for example.

Occasionally clean the ventilation slots on the battery using a soft brush that is clean and dry.

A significantly reduced operating time after charging indicates that the battery has deteriorated and must be replaced.

Follow the instructions on correct disposal.