Shock-warning function

The measuring tool has a shock-warning function. After position changes or shock to the measuring tool, or in case of ground vibrations, it keeps the measuring tool from levelling in at changed positions, and thus prevents errors caused by a change in the measuring tool's position.

To activate shock warning:

The shock-warning function is switched on by default. It is activated approximately 15 s after the last press of a button.
During activation, the shock-warning function indicator (13) flashes green. The indicator lights up continuously green after activation.

Shock warning actuated:

If the position of the measuring tool is changed or a strong shock is registered, the shock warning is triggered. The rotation of the laser is stopped, the laser beam is switched off, the slope angle indicator (8) and the shock-warning function indicator (13) flash red.

  1. Briefly press the  button.
  1. The shock-warning function is reset and the measuring tool starts the levelling. It returns to the levelling settings that it had before the shock-warning function was triggered.

As soon as the measuring tool has levelled in, it starts automatically in rotational operation.

  1. Now check the position ‌of the laser beam at a reference point and, if necessary, correct the height or alignment of the measuring tool.

Switching the shock-warning function on and off:

  1. Press and hold the  button until the shock-warning function indicator (13) changes colour (after approx. 3 s):
    Flashing from green to red when the shock-warning function is switched off,
    flashing from red to green when the shock-warning function is switched on.
When the shock warning is triggered, first press the  button briefly to reset the shock-warning function before you can switch off the shock-warning function.

The shock-warning function is activated 15 s after switching on (the shock-warning function indicator (13) lights up continuously green).