Checking the levelling accuracy in a horizontal position

For a reliable and precise result, it is recommended that you check the levelling accuracy on a free measuring distance of 30 m on firm ground in front of a wall. Carry out a complete measuring procedure for each of the two axes.

  1. Mount the measuring tool in a horizontal position 30 m from the wall on a tripod, or place it on a firm, level surface.
  2. Switch on the measuring tool.
  1. Once levelling is complete, mark the centre of the laser beam on the wall (point Ⅰ).
  1. Turn the measuring tool 180° without adjusting the height.
  2. Allow the measuring tool to level in.
  3. Mark the centre of the laser point on the wall (point Ⅱ).
  4. Ensure that point Ⅱ is vertically over or under point Ⅰ.
  5. Rotate the measuring tool by 90° and repeat the measuring process for the other axis.

The maximum permitted deviation on the 30 m measuring distance is as follows: ±1.5 mm. The discrepancy d between points Ⅰ and Ⅱ must therefore amount to no more than 3 mm for each of the two measuring processes.